Before using MXB E infrared elevator door detector(elevator light curtain) for elevator, please read this specification carefully and keep this specification for the future installation.
Please check if anything is missing from the following packing list:
|
ITEM |
QUANTITY |
1 |
POWER SUPPLY CONTROL UNIT |
1PCS |
2 |
DURABLE FLEXIBLE CABLE |
2PCS |
3 |
TRANSMITTER |
1PCS |
4 |
RECEIVER |
1PCS |
5 |
USER MANUAL |
1COPY |
6 |
MOUNTING ACCESSORIES |
1SET |
Technical Date:
Number of beams(Max.) |
128 |
Response time(MS) |
65 |
Range of detection |
0-3000mm |
Active protection height |
20-1841mm |
Vertical mounting tolerance |
+/- 20mm/10° |
Horizontal mounting tolerance |
+/- 5mm/7° |
Light immunity(LUX.) |
100000 |
Operating temperature |
-20℃——+65℃ |
LED indicators |
Green:power supply; Red:signal indicators |
Housing material |
Aluminum alloy,finished black |
Housing dimension(L) |
2000mm |
Housing dimension(W) |
55mm |
Housing dimension(D) |
20mm |
Power consume |
3w |
System marking |
CE |
|
Installation sketch for light curtain MXB E 
Interruption happening; Power LED on(220/110VAC only),working led off,buzzer is on after 10s,continue in for 20s,automatically stop and change to mechanical edge working mode.
System is in a self detection mode,working LED blinking ,when there is no interruption for 6s, changes back to normal mode.
System Connection
The system has been designed to connect to the door operator or lift controller directly. When the infra-red beams are obstructed, a system trigger occurs and switches a relay or transistor output. This is used by the door/lift controller to re-open the doors . The standard output is relay contact 1 opend 1 cloesd.
Power supply unit- AC220V
The model PWSMXB-220 power supply is used if an AC220V50/60HZ supply ovltage is available. It provides a regulated DC supply for the detector and a relay output for connection to the door re-open circuit.
Power supply unit- AC110V
The model PWSMXB-110 power supply is used if an AC110V50/60HZ supply ovltage is available. It provides a regulated DC supply for the detector and a relay output for connection to the door re-open circuit.
Power supply unit- DC24V
The model PWSMXB-24 power supply should be used only if an unregulated DC supply voltage (15V-30V) is available .It provides a regulated DC supply for the detectors and a relay output for onnection to the door re-open circuit.
|